The DruvaTEC 250 m3 MB400 single-stage high-pressure manual gas manifold, based on the Manyflow unit, is designed for high-flow oxygen and inert gas applications, with safety features like non-return valves, a central shut-off valve, and a flashback arrestor.
The Druva MB400 single-stage high-pressure manifold, based on the Manyflow unit, is designed for high-flow applications and can be used with oxygen and inert gases. Primarily intended for cylinder bundle service, it features non-return valves at the Manyflow inlets, separate isolating valves, and a central inlet shut-off valve. The MR400 regulator includes high- and low-pressure gauges, a pressure relief valve, and a low-pressure ball valve downstream of the regulator. All components are securely mounted on a stabilising stainless steel wall bracket.
The MB400 acetylene gas manifold is designed and manufactured in accordance with ISO 14114. The Manyflow unit is tested and approved per ISO 15615, and the high-pressure automatic quick-acting shut-off valve and MR60 pressure regulator meet relevant standards. The system also includes a pressure relief valve, high and low-pressure gauges, and a low-pressure flashback arrestor (Simax 3) that complies with EN 730-1 and ISO 5175. The outlet ball valve is mounted downstream of the flashback arrestor.
The Druva MB400 single-stage high-pressure manifold, based on the Manyflow unit, is designed for high-flow applications and can be used with oxygen and inert gases. Primarily intended for cylinder bundle service, it features non-return valves at the Manyflow inlets, separate isolating valves, and a central inlet shut-off valve. The MR400 regulator includes high- and low-pressure gauges, a pressure relief valve, and a low-pressure ball valve downstream of the regulator. All components are securely mounted on a stabilising stainless steel wall bracket.
The MB400 acetylene gas manifold is designed and manufactured in accordance with ISO 14114. The Manyflow unit is tested and approved per ISO 15615, and the high-pressure automatic quick-acting shut-off valve and MR60 pressure regulator meet relevant standards. The system also includes a pressure relief valve, high and low-pressure gauges, and a low-pressure flashback arrestor (Simax 3) that complies with EN 730-1 and ISO 5175. The outlet ball valve is mounted downstream of the flashback arrestor.
Product Line | druvaTEC - Central Gas Systems |
---|---|
Gas Properties | Oxygen, inert |
Applications | Laser or Plasma Cutting, Industry, Marine |
Regulator type (O, Inert, CO2) | MR400 |
Regulator type (A) | MR60 |
Body, bonnet material (O, Inert, CO2) | Brass |
Body, bonnet material (A) | Brass (Cu less than 65 %) |
Connectors and fittings material (O, Inert, CO2) | Brass, stainless steel |
Connectors and fittings material (A) | Brass (Cu less than 65 %), stainless steel |
Diaphragm material (O, Inert, CO2) | Butyl |
Diaphragm material (A) | Chloroprene |
Seat sealing material (O, Inert, CO2) | PA |
Seat sealing material (A) | PTFE |
Wall bracket | Stainless steel |
Maximal inlet pressure (O, Inert, CO2) (psi-bar) | 300 (4350) |
Maximal inlet pressure (A) (psi-bar) | 25 (363) |
Maximal flow rate (O, Inert, CO2) | 400 Nm3/h |
Maximal flow rate (A) | 25 Nm3/h |
Nominal flow rate (O, Inert, CO2) | 250 Nm3/h |
Nominal flow rate (A) | 19 m3/h |
Temperature range | from -20 °C to 60 °C |
Manifold Type | Three sources - manual change over |
Regulation Type | Single stage |
Applications | Laser or Plasma Cutting, Industry, Marine |
Loading... ... loading table ... |
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 |
---|---|---|---|---|
0768098 | O, D, N, CO2 | 300, 20 / 4350, 290 | W21,8×1/14“ | G3/4“, DN15 |
0768097 | A | 25, 1.5 / 363, 22 | W21,8×1/14“ LH | G3/4“, DN15 |
You can have confidence in our global network
Copyright © 2025 GCE. All rights reserved.
GCE Group
Turmstrasse 30
6321 Steinhausen
Zug
Switzerland